Goals and Overall Approach
We will use multiple packages and pieces of software for white matter (and gray matter/cerebro spinal fluid (CSF)) segmentation.
The overall approach will be, with the required packages in parentheses:
- N4 Inhomogeneity Bias-Field Correction (
extrantsr
andANTsR
) - Brain extraction using BET and additional tools (
extrantsr
andfslr
) - FAST for tissue-class segmentation. (
fslr
)
Installing Packages
Below is a script to install all the current development versions of all packages. The current fslr
packages depends on oro.nifti (>= 0.5.0)
, which is located at muschellij2/oro.nifti
or bjw34032/oro.nifti
.
Note, the ITKR
and ANTsR
packages can take a long time to compile. The extrantsr
package builds on ANTsR
and makes some convenience wrapper functions.
devtools::install_github("muschellij2/oro.nifti") devtools::install_github("muschellij2/fslr") devtools::install_github("stnava/cmaker") devtools::install_github("stnava/ITKR") devtools::install_github("stnava/ANTsR") devtools::install_github("muschellij2/extrantsr") install.packages("scales")
Load in the packages
Here we will load in the required packages. The scales
package is imported just for the alpha
function, used below in plotting.
rm(list=ls()) library(fslr) library(extrantsr) library(scales)
Specifying FSL path
For fslr
to work, FSL must be installed. If run in the Terminal, the FSLDIR
environmental variable should be found using R
's Sys.getenv("FSLDIR")
function.
If run in an IDE (such as RStudio or the R GUI), R
must know the path of FSL, as set by the following code:
options(fsl.path="/usr/local/fsl/")
Image Filenames
Here we will set the image name. The nii.stub
function will strip off the .nii.gz
from img.name
.
img.name = "SUBJ0001-01-MPRAGE.nii.gz" img.stub = nii.stub(img.name)
N4 Bias Field Correction
The first step in most MRI analysis is performing inhomogeneity correction. The extrantsr
function bias_correct
can perform N3 or N4 bias correction from the ANTsR
package.
n4img = bias_correct( img.name, correction = "N4", outfile = paste0(img.stub, "_N4.nii.gz") ) ortho2(n4img)
Let us note that the image is of the head and a bit of the neck. We wish to perform white matter segmentation only on the brain tissues, so we will do brain extraction.
Brain Extraction
The extrantsr
function fslbet_robust
performs brain extraction. It relies on the fslr
function fslbet
which calls bet
from FSL. It also performs neck removal (remove.neck = TRUE
) and will perform BET once and then estimate a new center of gravity (COG) and then re-run BET. These functions are implemented in fslbet
specifically, but these have been re-implemented in fslbet_robust
in a slightly different way. fslbet_robust
will also perform N4 inhomogeneity correction, but as this has already been performed above, we will set correct = FALSE
.
For neck removal, a template brain and mask must be specified. We will use the T1, 1mm resolution, MNI brain included with FSL's installation.
bet = fslbet_robust(img = n4img, retimg = TRUE, remove.neck = TRUE, robust.mask = FALSE, template.file = file.path( fsldir(), "data/standard", "MNI152_T1_1mm_brain.nii.gz"), template.mask = file.path( fsldir(), "data/standard", "MNI152_T1_1mm_brain_mask.nii.gz"), outfile = "SUBJ0001-01-MPRAGE_N4_BET", correct = FALSE)
The results look good – the brain tissue is kept (in red) only. Not much brain tissue is discarded nor non-brain-tissue is included.
ortho2(n4img, bet > 0, col.y=alpha("red", 0.5))
FAST Image Segmentation
Now that we have a brain image, we can use FAST for image segmentation. We will use the fslr
function fast
, which calls fast
from FSL. We will pass the -N
option so that FAST will not perform inhomogeneity correction (different from N4 and N3), because we had performed this before.
fast = fast(file = bet, outfile = paste0(img.stub, "_BET_FAST"), opts = '-N')
White Matter Results
By default, FAST assumes 3 tissue classes, generally white matter, gray matter, and CSF. These are generally ordered by the mean intensity of the class. For T1-weighted images, white matter is the highest intensity, and assigned class 3
. Let's see the results:
ortho2(bet, fast == 3, col.y=alpha("red", 0.5))
Gray Matter / CSF Results
We can also visualize the classes for 1
and 2
for CSF and gray matter, respectively.
ortho2(bet, fast == 1, col.y=alpha("red", 0.5), text="CSF Results")
ortho2(bet, fast == 2, col.y=alpha("red", 0.5), text="Gray MatternResults")
The results indicate good segmentation of the T1 image. The fslr
function fast
result in more than the tissue-class segmentation, see the other files output:
list.files(pattern=paste0(img.stub, "_BET_FAST")) [1] "SUBJ0001-01-MPRAGE_BET_FAST_mixeltype.nii.gz" [2] "SUBJ0001-01-MPRAGE_BET_FAST_pve_0.nii.gz" [3] "SUBJ0001-01-MPRAGE_BET_FAST_pve_1.nii.gz" [4] "SUBJ0001-01-MPRAGE_BET_FAST_pve_2.nii.gz" [5] "SUBJ0001-01-MPRAGE_BET_FAST_pveseg.nii.gz" [6] "SUBJ0001-01-MPRAGE_BET_FAST_seg.nii.gz"
Conclusions
It's a exciting time to be working in neuroimaging in R
. The fslr
and ANTsR
packages provide functionality to perform operations for neuroimaging processing. I will be doing a series on some of the options for analysis in the coming weeks. The code for this analysis (and the data) is located at https://github.com/muschellij2/HopStat/blob/gh-pages/White_Matter_Segmentation_in_R/
Notes
The fslr
function ortho2
is a rewrite of the oro.nifti::orthographic
function, but with different defaults and will set values of 0
in the second image (y
argument) to NA
.
R-bloggers.com offers daily e-mail updates about R news and tutorials about learning R and many other topics. Click here if you're looking to post or find an R/data-science job.